Hangzhou Dry Air Intelligent Equipment Co., LTD is a professional China Lithium Battery NMP Recovery Unit Suppliers and custom Lithium Battery NMP Recovery Unit Manufacturers. With a world-class team of research and development, marketing and service engineers, we have been researching and developing cutting-edge technology in environment and air treatment industry, our products are widely used in aviation, environmental protection, lithium battery, food, architecture, pharmaceutical, and many other industries, moreover, we have experience of providing integrated solutions and technical support for large satellite launch base, important cabin of Chinese Navy vessels, Chinese Army's warehouses. The company which was founded in 2004, is located in Qingshan science and technology industrial zone in the west of Hangzhou, covers an area of 25000 square meters and has more than 200 staff.
Industry knowledge

How to Install Lithium Battery NMP Recovery Unit?

Installing a Lithium Battery NMP (N-Methyl-2-pyrrolidone) Recovery Unit can be a complex process that requires technical knowledge and expertise. It is important to follow the manufacturer's instructions and guidelines for installation to ensure the unit operates safely and efficiently.

Here are some general steps to follow for installing a Lithium Battery NMP Recovery Unit:

Choose a suitable location for the unit: The location should be well-ventilated, dry, and away from any sources of heat or ignition.

Mount the unit: The unit should be mounted securely to a stable surface using the appropriate mounting hardware. The mounting surface should be able to support the weight of the unit and any associated components.

Connect the power supply: Connect the power supply to the unit according to the manufacturer's instructions. Make sure the power supply is compatible with the unit's voltage and current requirements.

Install the plumbing: Install the plumbing according to the manufacturer's instructions. This typically involves connecting hoses and fittings to the unit and the battery system. Use appropriate plumbing techniques and materials to ensure a secure and leak-free connection.

Configure the unit: Configure the unit according to the manufacturer's instructions. This may involve setting operating parameters and calibrating sensors.

Test the unit: Test the unit to ensure it is operating properly. This may involve running a test cycle with a sample battery system or performing a leak test on the plumbing.

Monitor and maintain the unit: Monitor the unit regularly to ensure it is operating correctly and perform any necessary maintenance as recommended by the manufacturer.

It is important to note that the installation process may vary depending on the specific Lithium Battery NMP Recovery Unit being installed. Always refer to the manufacturer's instructions and guidelines for detailed installation instructions and safety precautions. If you are unsure about any aspect of the installation process, consult a qualified professional or contact the manufacturer for assistance.

The Structure of Lithium Battery NMP Recovery Unit

A lithium battery NMP (N-Methyl-2-pyrrolidone) recovery unit is designed to reclaim and purify NMP solvent used in the manufacturing process of lithium-ion batteries. The unit typically consists of several key components, including:

Distillation Column: The distillation column is the main component of the NMP recovery unit. It is used to separate the NMP solvent from the impurities and other by-products. The column typically consists of a series of trays or packing material to provide maximum surface area for the separation of NMP from impurities.

Heat Exchanger: The heat exchanger is used to control the temperature of the NMP solvent as it passes through the distillation column. The heat exchanger is typically connected to a cooling tower or chiller to remove the heat generated during the distillation process.

Condenser: The condenser is used to condense the NMP vapors into liquid form as they are released from the distillation column. The condenser typically consists of a series of tubes or plates that provide maximum surface area for efficient cooling.

Reboiler: The reboiler is used to provide heat to the distillation column to facilitate the separation of NMP from impurities. The reboiler typically consists of a heating coil or steam jacket that surrounds the bottom of the distillation column.

NMP Storage Tank: The NMP storage tank is used to store the purified NMP solvent once it has been separated from the impurities. The tank is typically made of stainless steel and is equipped with level sensors, temperature sensors, and pressure sensors to monitor the NMP storage conditions.

Control System: The control system is used to monitor and control the entire NMP recovery unit. It typically consists of a programmable logic controller (PLC) and human-machine interface (HMI) that allow operators to monitor the process and adjust the operating parameters as necessary.

Overall, the lithium battery NMP recovery unit is an essential component of the lithium-ion battery manufacturing process, as it allows manufacturers to recycle and reuse NMP solvent, reducing waste and improving the efficiency of the production process.